(IC-756Pro II and IC-756Pro III User Manuals, p. 43) Select CW Press F-3 (KEYER). Press EXIT/SET. This will bring up the MEMORY KEYER MENU. Press F-4 (CW KEY). Press F-2 (V) to select "Rise Time". Set Rise Time to desired value (2 ~ 8 mS) by turning main tuning knob. Press EXIT/SET twice to exit menu, then press F-1 (SCOPE) to restore scope display.* *Note: If M.SCOPE is activated on the IC-756Pro III, the mini-scope will be displayed above the menu. Pressing F-1 will suppress the mini-scope and restore the normal scope. Also see Greg Ordy W8WWV's Icom IC756Pro CW Envelope Adjustments page. |
(IC-756Pro User Manual, p. 42) Select CW Press F-2 (KEYER). Press F-4 (CW KEY). Press F-2 (V) to select "Rise Time". Set Rise Time to desired value (2 ~ 8 mS) by turning main tuning knob. Press EXIT twice to exit menu, then press F-1 (SCOPE) to restore scope display. |
(IC-746Pro User Manual, p. 43) Select CW -
Press MENU to select M1, then press F4 KEY to select the memory keyer menu. Press F5 SET to select keyer set mode. Press F1 (^) or F2 (V) to select "Rise Time". Set Rise Time to desired value (2 ~ 8 mS) by turning main tuning knob. Press F3 for 1 sec. to return to default value. Press MENU 2 times to return to M1. |
|